Enter using the front panel, RC or left mouse click to access the PTZ Setup

window as shown below.

LCDDVR4 supports 2 type of protocol cameras; Pelco-D and Pelco-P protocols.

Adjust the RS485 setting according to the PTZ protocol camera and then match

the Address, Protocol, and Baudrate setup to the camera settings.

To setup PTZ protocol camera, change the Channel to the PTZ camera. Set

the dome address number or dome’s identification number ranges from 0~255.

Most protocol dome cameras are default to address 1, be sure to set the address

to match with the actual dome address setting. Next, select the type of PTZ

protocol dome camera used; whether it is Pelco-D or Pelco-P as other protocols

is not supported. Finally, change the Baudrate according to the PTZ requirement

setting. Here is an overview on how PTZ Setup should be configured:
CHANEL:Select a camera channel where PTZ camera is connected.
ADDRESS:Dome’s address “0-255” (PELCO-D) and”0-31” (PELCO-P) ), the
system default setting is 1 (Set based on the dome’s address).
PROTOCOL: Select “PELCO-D”, “PELCO-P”(Set based on dome’s protocol).
BAUD RATE: Press SEL/EDIT button on the front panel, RC or left mouse
click on red arrows to adjust the value:

1200bps, 2400bps, 4800bps (default),

9600bps, or 19200bps (Set based on the dome’s baud rate requirement, refer-
ence dome manual as needed).
SPEED: Ranges from 1-10, this is the speed of the dome movements when it is
rotating from one position to the next. Set the speed to 10 for fast dome rotation-

Advertising