Harrington Hoists and Cranes TCR Hoist - (1/4-6 Ton) User Manual

Page 17

Advertising
background image

17

3.6.2



Piping - Pipe should be sized to accommodate the hoist airflow requirements.

Table 3-1

gives recommended pipe sizes.

Table 3-1

Air Supply Pipe and Hose Sizes

Model

Diameter of Supply

Pipe

Diameter of Supply

Hose

TCR250P, 250C, 500P, 500C, 1000P, 1000C
TCR1000P2, 1000C2, 2000P2, 2000C2

Inside diameter

0.75 inch or larger

Inside diameter

0.5 inch or larger

TCR3000P, 3000C
TCR6000P2, 6000C2

Inside diameter

1.0 inch or larger

Inside diameter

0.75 inch or larger

3.6.3



Hoses - The connection from the air supply system piping to the hoist must be

made with a flexible pressure hose. Due to normal line losses in air supply lines:

Do not use hose smaller than specified in

Table 3-1

, and

Limit the length of the hose to that specified in

Figure 3-3

.

If your application exceeds these requirements consult factory.

Figure 3-3

Typical Arrangements of Filter, Regulator and Lubricator and

Maximum Air Supply Hose Lengths

3.6.4



Fittings - Important considerations regarding fittings in the hoist's air supply

include:

When connecting air supply components, remove all dirt or debris from the connecting surfaces of
the hoses, pipes, fittings, or threaded fasteners to prevent contaminants from entering the hoist.

Keep airflow restrictions such as quick disconnect fittings, bends, elbows, and adapters to a
minimum.