Table 8-1

Troubleshooting Guide

Symptom

Cause

Remedy

Unable to lift rated load

Lack of air pressure or loss of air
supply.

Repair or adjust air supply or filters.

Improper adjustment of load limiter.

Adjust Load Limiter. See

Section 7.1

.

Air leak between the two chambers
in the Top Cover

Correct or repair to eliminate air leak.

Hoist moving in wrong
direction (pendant control)

Pendant control tubes are terminated
to incorrect ports on hoist body.

Connect the control tubes in
accordance with

Section 7.4

.

Hoist lowers but will not lift

Hoist is overloaded.

Reduce load to hoist rated capacity.

Faulty pendant control or control
tube(s)

Repair or replace pendant control or
control tube(s)

Lack of air pressure or partial loss of
or leakage in air supply.

Repair or adjust air supply or filters.

Hoist continues running after
pendant or cord is released

Main Spool sticking

Inject approx. 20 drops of oil into inlet
port to lubricate the main spool. If
spool still sticks, repair at service
facility.

Main Spool spring broken

Repair at service facility

Main Spool leaking

Repair at service facility

Mis-alignment of Limit Shaft with
Bottom Plate (TCR3000/6000 only)

Loosen Bottom Plate and re-align so
that Limit Shaft operates freely.

Valve in Pendant Handle stuck

Repair at service facility

Hoist drifts excessively when
hoist is stopped

Brake is not holding.

Repair brake at service facility.

Motor vanes leaking.

Replace motor vanes and springs at
service facility.