Componet – IAI America PCON-CFA User Manual

Page 184

Advertising
background image

4. SCON-CA


178

CompoNet

Setting of parameter No. 25

Force control mode 1

Force control mode 2

6 7

Category

Port No.

Symbol

Signal name

Symbol

Signal name

0

PC1

ST0

Start position 0

1

PC2

ST1

Start position 1

2

PC4

ST2

Start position 2

3

PC8

ST3

Start position 3

4 PC16

Command position number

ST4

Start position 4

5 -

-

6 -

-

7 -

Cannot be used.

-

Cannot be used.

8

CLBR

Load cell calibration command

CLBR

Load cell calibration command

9

BKRL

Forced brake release

BKRL

Forced brake release

10

RMOD Operation

mode RMOD

Operation

mode

11

HOME

Home return

HOME

Home return

12 *STP

Pause

*STP

Pause

13

CSTR

Positioning start

-

Cannot be used.

14 RES

Reset

RES

Reset

PLC Output

ĺ

SCON Input

15

SON

Servo ON command

SON

Servo ON command

0

PM1

PE0

Completed position number 0

1

PM2

PE1

Completed position number 1

2

PM4

PE2

Completed position number 2

3

PM8

PE3

Completed position number 3

4 PM16

Completed position number

PE4

Completed position number 4

5

TRQS

Torque level status

TRQS

Torque level status

6

LOAD

Load output judgment status

LOAD

Load output judgment status

7

CEND

Load cell calibration complete

CEND

Load cell calibration complete

8

PZONE/

ZONE1

Position zone/

Zone 1

PZONE/

ZONE1

Position zone/

Zone 1

9

RMDS Operation

mode RMDS

Operation

mode

10

HEND

Home return complete

HEND

Home return complete

11

PEND

Positioning complete signal

PEND

Positioning complete signal

12

SV

Operation ready

SV

Operation ready

13

*EMGS

Emergency stop

*EMGS

Emergency stop

14 *ALM

Alarm

*ALM

Alarm

SCON Output

ĺ

PLC Input

15

*BALM

Battery alarm

*BALM

Battery alarm

* Indicates a signal that is normally ON.

The signals denoted by “Cannot be used” are not controlled. (ON/OFF statuses of these signals are
indeterminable.)

Advertising
This manual is related to the following products: