2. ACON-C/CG,

PCON-C/CG

13


[4] Full Direct Value Mode: This is the operation method with all the values (“Target Position”, “Speed”,

“Acceleration/Deceleration”, etc.) related to the position control set up directly by
using the numerical values.
Number of occupied bytes: 32 bytes





















[5] Remote I/O Mode 2: This is the operation method using EtherCAT(R), instead of PIO (24V I/O). The

current position and command current value reading functions are added to the
functions of [1].
Number of occupied bytes: 12 bytes























Target Position : 100.00mm

Positioning Band ; 0.10mm

Speed Setup ; 100.0mm/s

Acceleration : 0.30G

Deceleration : 0.30G

Pressing Current Value : 50%

Load Current Threshold : 0

Zone + : 50.00mm

Zone - : 30.00mm

Actuator

ACON or PCON applicable to
EtherCAT(R)

ACON or PCON applicable
to EtherCAT(R)

ACON or PCON not
applicable to EtherCAT(R)

Communication
cable

Flat cable

In the case of the connection using
EtherCAT(R)

In the case of the
connection using PIO