2. ACON-C/CG,

PCON-C/CG

38

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal Type

Bit

Symbol

Contents

Details

Current

Position

32-bit

data

-

32-bit signed integer indicating the current position
The setting unit is 0.01mm.
(Example) Reading:000003FF

H

=1023 (decimal)

=10.23mm
*

When the value is read in hexadecimal notation, the

negative figure is expressed as a complement of 2.

2.8 (2)

Command

Current

32-bit

data

-

32-bit integer
The electrical current presently specified by a command is indicated.
The setting unit is mA.
(Example) Reading:000003FF

H

=1023 (decimal)

=1023mA

2.8 (2)

Current

Speed

32-bit

data

-

32-bit signed integer indicating the current position
The current speed is indicated.
Positive value: The actuator is moving in the direction opposite home.
Negative value: The actuator is moving in the direction of home.
The setting unit is 0.01mm/sec.
(Example) Reading:000003FF

H

=1023 (decimal)

=10.23mm/sec
*

When the value is read in hexadecimal notation, the

negative figure is expressed as a complement of 2.

2.8 (2)

Alarm Code

16-bit

data

-

16-bit integer
When an alarm is issued, the alarm code is output.
When any alarm is not issued, it is “0

H

”.

Refer to the Operation Manual for the controller main body for the details
of the alarms.

2.8 (2)

b15 EMGS

Emergency stop: An emergency stop is actuated when this signal turns
ON.

2.6.7 (2)

b14 PWR

Controller ready : This signal turns ON when the controller becomes
ready.

2.6.7 (1)

b13

ZONE2 Zone 2:“ON” for the current position within the zone set range

2.6.7 (12)

b12

ZONE1 Zone 1:“ON” for the current position within the zone set range

2.6.7 (12)

b11

b10

b9

-

Unavailable -

b8 RMDS

Operation Mode Status:
This signal is OFF when the current mode is AUTO, or ON when the
current mode is MANU.

2.6.7 (19)

b7

b6

- Unavailable

-

b5 PSEL

Pressing and a Miss: This signal turns ON when the actuator missed
the work part in push-motion operation.

2.6.7 (23)

b4 SV

Operation preparation end: This signal turns ON when the servo turns
ON.

2.6.7 (5)

b3

ALM

Alarm: This signal turns ON when an alarm occurs.

2.6.7 (3)

b2

MOVE

Moving Signal: This signal remains ON while the actuator is moving.

2.6.7 (9)

b1 HEND

Home return completion: This signal turns ON when home return is
completed.

2.6.7 (6)

PLC Input

Status
Signal

b0 PEND

Positioning completion signal: This signal turns ON when positioning is
completed.

2.6.7 (10)