IAI America PCON-CFA User Manual

Page 55

Advertising
background image

2. ACON-C/CG,

PCON-C/CG

49

(1)

PLC address configuration (* “n” shows the node address of each axis.)

Parameter

No.84

ACON/PCON side

DI and input register

PLC side output

address (bytes)

ACON/PCON side

DO and output register

PLC side input

address (bytes)

Port No.0 to 15

n, n+1

Port No.0 to 15

n, n+1

n+2, n+3

Occupied area

n+2, n+3

4

n+4, n+5

n+4, n+5

n+6, n+7

Current Position

n+6, n+7

n+8, n+9

n+8, n+9

Occupied area

n+10, n+11

Command Current

n+10, n+11

(Note) The areas denoted by Occupied area cannot be used for any other purpose.

Also, exercise caution to avoid node address duplication.

(2)

I/O Signal Allocation for each Axis

The I/O signals of each axis consist of 6 input words (channels) and 6 output words (6 words=12 bytes) in the
I/O areas.

z The areas controlled by port number are controlled using ON/OFF bit signals.

z The current position is a 2-word (32-bit) binary data (unit: 0.01 mm).

z The command current is expressed using 2-word (32 bits) binary data (Unit: 1mA).

PLC

output

Address

(* “n” shows the node address of each axis.)

Controller

input port

number

1 word (1CH) = 16 bits


1 word = 2 bytes =16 bits

n+0, n+1