2. ACON-C/CG,

PCON-C/CG

77


(4) Data change during movement

In the half direct mode or full direct mode, the value currently set to a given resister among the resisters for
target position data, acceleration/deceleration data, speed data, positioning band and push-motion
current-limiting value, can be changed while the actuator is moving.
After changing the data, turn “ON” the positioning command (DSTR) for more than tdpf.
Also, after turning “OFF” the DSTR, set aside some time for “twcsON + twcsOFF” or more, until the next
DSTR is turned “ON”.
The example is shows as follows, where the speed and acceleration/deceleration data items have been
changed.



























twcsON • Yt

዇xt዇3(msec)

twcsOFF • Yt

዇xt዇3(msec)

*Yt

዇xt ” tpdf ” Yt዇xt዇3(msec)









Set value of

speed or acceleration/

deceleration

Actuator

speed

Velocity n2

Velocity n3

[1]

[2]

[3]

Caution

1. When the speed has not been set or it is set to “0”, the actuator is not moved, but an alarm is not

issued.

2. When the speed setting is changed to “0” during the movement, the actuator is decelerated and

stopped, but an alarm is not issued.

3. Even when the acceleration/deceleration data only is changed during the movement, the setting of

the target position data is required.

4. Even when the target position data only is changed during the movement, the setting of the

acceleration/deceleration data is required.