6. Appendix

257

6. Appendix

6.1 Setup of Connection with Omron’s Master Unit

The following devices and software are required to connect to an Omron master.

[1] PLC CPU unit:

(Ex) CJ1G-CPU43H

[2] EtherCAT(R) master unit (Position control unit):

(Ex) NC-882

[3] Setting software:

CX-One V4.0 or later CX-Programmer V9.11 or later

[4] IAI controller designed for EtherCAT(R)

6.2 Automatic Network Setup

The setup procedure is as follows:

[1]

Open CX-Programmer. Double-click I/O Table/Unit setting listed on the project tree, and open the I/O
table.

















[2] Double-click the field for CJ1W-NC882 position control unit (EtherCAT(R) communication type) on the

CPU rack tree and launch the position control unit setting tool (hereinafter referred to as the "NCF
tool").