Adjustment, Limit switch adjustment, Gate system test procedures – LiftMaster SL575 Heavy-Duty Commercial Slide Gate Operator User Manual

Page 14: Rpm sensor (hall effect) adjustment

Advertising
background image

14

NOTE: Make sure the limit nuts are positioned between the limit
switch actuators before proceeding with adjustments.

1. Remove control panel cover and locate the limit switch

assembly.

2. Disengage the unit’s manual disconnect (see page 12), then

manually open the gate to its full open position (note direction
of limit nut travel).

3. Adjust the open limit nut by depressing the retaining bracket

to allow nut to spin freely. Adjust open limit nut so that it trips
the open limit switch. After adjustment, release plate and
ensure it seats fully in slots of both nuts.

4. Manually close the gate to its full closed position.

5. Disengage the retaining bracket and rotate the close limit nut

until it trips the close limit switch.

6. Re-engage the retaining bracket into both limit nuts and also

re-engage the manual disconnect.

LIMIT SWITCH ADJUSTMENT

To reduce the risk of SEVERE INJURY or DEATH:
• Disconnect power BEFORE performing ANY adjustments.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

WARNING

CAUTION

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

RPM SENSOR (HALL EFFECT) ADJUSTMENT

NOTE: Normally the RPM Sensor (hall effect) does not need
adjustment, but may go out of alignment due to shipping
vibration or rough handling.

These operators use an internal entrapment protector system.
This system consists of the control board, magnet, and
RPM sensor (hall effect). It may become necessary to adjust the
sensor for correct alignment. To do so please perform the
following steps:

1. The sensor must be

centered over the magnet
wheel. Adjust with
horizontal screws.

2. The sensor must be

level.

3. The sensor air gap

should be adjusted to
.010 - .015 of an inch.
(The thickness of a
business card may be
used to gauge the
correct distance.) Adjust
with vertical screws.

Vertical Adjustment

Screws

Horizontal Adjustment
Screws

Magnet

RPM Sensor (Hall Effect)

.010 - .015"

(.25 - .38 mm)

Air Gap

DIRECTION OF

GATE TO OPEN

RIGHT

(Factory Default)

LEFT

OPEN

LIMIT

A

B

CLOSE

LIMIT

B

A

GATE SYSTEM TEST PROCEDURES

Make sure that the gate’s path is clear from any obstructions and that all associated gate hardware is properly mounted and
secured.

1. With the power off, manually move the gate to the fully closed position.

2. At the closed position, turn the power on and observe the control board’s diagnostic and limit LEDs. When power is turned on,

these LEDs should flash simultaneously for a few seconds.

3. Locate the 3-button control that is built into the electrical box.

4. Push the open button and observe the operator’s behavior. The gate should begin opening. If the operator fails to open or has

difficulty opening, refer to the troubleshooting section.

5. Once at the open limit, the gate will stop. Push the close button and observe the operator’s behavior. If the operator fails to close or

has difficulty closing, refer to the troubleshooting section.

6. While the gate is closing, push the stop button. The gate should now stop.

7. Push the close button to return the gate to the fully closed position.

Limit Switch

Limit Nut A

Limit Switch

Limit Nut B

Retaining
Bracket

Depressed Plate

Each notch of the nut indicates an
estimated 1" (2.5 cm) of gate travel

LIMIT DIRECTION

A D J U S T M E N T