NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of
this receiver and/or remote control are prohibited, except for changing the code setting or
replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept ANY interference received, including interference that may cause undesired operation.

FIGURE 3

PROGRAMMING THE REMOTE TO THE RECEIVER

1. Pry open the front panel of receiver case with a coin or a

screwdriver. Re-connect power to operator (Figure 3).

2. Press and release the "learn" button on the receiver. The learn

indicator light will glow steadily for 30 seconds.

3. Within 30 seconds, press and hold the button on the hand-held

remote that you wish to operate your gate operator.

The opener will now operate when the push button on either the
receiver or the remote control is pressed.

Repeat Steps 2 and 3 for each remote control that will be used to
operate the gate operator.

TO ERASE ALL REMOTE CONTROL CODES

Press and hold the “learn” button on the receiver panel until the
indicator light turns off (about 6 seconds). All remote codes are
now erased. Then follow the steps above to reprogram each
remote control.

FIGURE 2

ACCESSORY WIRING

Terminals 6 & 5 (Com) - Soft Open
These terminals are intended for use as a general open control.
Accessories that may be wired to this input include: Telephone
Entry Systems, Radio Receiver (Commercial Applications), Exit
Loop Detector, Keypads, 7-Day Timer. NOTE: Will not override a
double entrapment (signalled by the gate stopped and entrapment
alarm on).

REMOTELY MOUNTED STOP/RESET CONTROL WIRING

• This control will function as a Stop/Reset command and is to be

wired within line of sight of the gate.

• Wire Stop/Reset control station to terminals 3 and 5 on the

control box on the operator. Make sure that all Stop/Reset
controls are wired in series.

M

M

Jumper

Output
Duration
Terminals

Jumper

Output
Duration
Terminals

MOMENTARY
OPERATION

CONSTANT
OPERATION

24V

12V

HIGH

NORM

C

P2

M

Output Duration
Terminals

Power Supply Jumper

Security Mode

OPEN RECEIVER

OPENING RECEIVER

Indicator Light

Learn Button

Connect
Antenna

1

2

3

4

5

6

7

8

9 10 11 12 13 14

3

6

9

#

2

5

8

0

1

7

Soft Open

1

2

3

1 2 3 4 5

6 7

Control
Conduit

Control
Conduit

Stop/Reset
Button

Stop/Reset
Button

Advertising