Three phase schematic – LiftMaster SL575 Heavy-Duty Commercial Slide Gate Operator User Manual

Page 33

Advertising
background image

33

A1

A1

Y/BK

ON/OFF
SWITCH

ON

OFF

40-32357J

A

XFMR

(TB2)

J2 PLUG
ON PCB

POWER IN
SEE NOTE 1

AB

CD

TO MOTOR

SEE NOTE 5
MOTOR
OVERLOAD

SEE NOTE 5

SEE NOTE 5

SEE NOTE 5

AUXILIARY RELAY
EXTERNAL OVERLOAD

LINE

BLACK (SL595 ORANGE)

SEE NOTE 3

LOAD
24VAC/60VA

BLUE

YELLOW

FUSE 3.2A

RADIO

TERMINAL

BLOCK

FACTORY

INSTALLED RADIO

(100db)
SAFETY
ALARM

-

+

1

2

3

4

5

6

7

8

9

10

12

13

14

15

16

17 18 19

20

11

(TB1)

PURPLE

PUR/WHT

RESET

ST

OP

GREEN

YEL/BLK

BROWN

ORANGE

GREEN

GRA

Y

BLACK

BLACK

BLUE

WHITE

RED

OR/BLK

BLUE

OR

TB1-7

GRN

TB1-4

Y/BK

TB1-5

OPEN

CLOSE

STOP

TB1-5

J1-5

Y/BK

RESET

RADIO

SHADO

W

VDC COM

CLOSE

ST

OP

SOFT OPEN

HARD OPEN

INTERR

UPT

OPEN CLOSE

EDGE/PHOTO

EYE

MASTER
SECOND

MAGLOCK

EXIT LOOP

FIELD CONNECTIONS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

J1

J4

1 2

J2

(GL CONTROL BOARD)

Y/BK

TO J2-1

CONTACTOR

TB2-CD

PURPLE

Y (SL595 WHT)

GY (SL595 GN)

PU (SL595 RD)

A1
13

5
3
1

A2
14

6
4
2

B

A1
13

5
3
1

A2
14

6
4
2

WHITE

ORANGE

TO J2-2

WHITE

BLACK

BK

BK

BK

BLUE

YELLOW

BLUE

YELLOW

RPM

BOARD

ORANGE

PURPLE

GREEN

GROUND

CONTACTOR A

CONTACTOR B

ORANGE

PURPLE

BLACK

RED

WHITE

11

10

9

8

7

6

5

2

1

4

3

TB1-15

TB1-3

ALARM

R1

R2

R3

R4

BLUE

BLACK

Y/BK

TB1-6

BROWN

GREEN

(SEE NOTE 6)

FREE EXIT LOOP

OR

PU

1

2

L/S “A”NC

C

L/S “B”NC

C

YEL/BLK

Y/BK

3

GY

1

3

2

BL-BK

BL-BK

230V
BRAKE
SOLENOID

230V CONNECTION

LOOP WIRING

(See NOTE 6)

TB1-5

R4

TB2-AB

TB2-CD

FREE EXIT

LOOP

HARNESS

(10 PIN)

TB1-8

TB1-3

TB2-AB

TB2-CD

INTERRUPT

LOOP

HARNESS

(10 PIN)

4

6

7

8

9

10

BK

BK

PU

7

8

9

4

5

6

460V CONNECTION

230V
BRAKE
SOLENOID

1

3

2

BL-BK

BL-BK

BK

BK

PU

7

8

9

4

5

6

Y

Y

575V CONNECTION

575V
BRAKE
SOLENOID

BL-BK

BL-BK

1

3

2

GY

BK

BK

PU

Y

GY

R1

R2

4

YELLOW

BK
BK

BK

L1

L2

L3

BK

SEE NOTE 5
EXTERNAL
OVERLOAD

NOTES:
1. Voltage: 208/230/460/575 volt 3 phase.
2. Horsepower: 1/2, 1 & 2 Hp.
3. Transformer primary voltage is the same as the operator line voltage. Secondary 24v/60va.

For reference primary wire colors: 120v black, 208v red, 230v orange, 460v purple, 575v grey

4. Terminal block in limit switch enclosure (SL595 only).
5. Three phase units are equipped with an internal pilot duty thermal overload device or an external line monitoring system.
6. When using a remote control or single button control station in lieu of the soft open feature, perform the following modifications to the operator:
• Remove the green wire from R4 of the radio block and mount the wire to terminal block TB1 position 6.
• Move the brown wire on terminal block TB1 position 6 (from radio block R4) to terminal block TB1 position 1.

24 VAC

RADIO

SIGNAL

TB2-20

TB2-19

TB2-18

TB2-17

W

W

A R N I N G

YELLOW

24 VAC ACCESSORY

POWER

INTERRUPT

LOOP

Y/BK

RD

BK

4

6

7

8

9

10

G

YELLOW

Y/BK

To protect against fire and electrocution:
• DISCONNECT power BEFORE installing or servicing operator.
• Replace ONLY with fuse of same type and rating. Fuse: 3AG, 3.2A, 120V, SLO-BLO

T H R E E P H A S E S C H E M A T I C

1/2 & 2 Hp.

Advertising