Teledyne LeCroy WaveExpert 100H Operators Manual User Manual

Page 271

Advertising
background image

Wave Expert

WE-OM-E Rev A

269

value on the instrument's screen. The remainder of the array is currently not used, and is
not accessible.

Within both types of script, you can call Excel.

Loading and Saving VBScripts

From the editing panel you can save your script and you can load a previous one. Should you forget
to save a script, please note that when you save your setup, it has your current scripts embedded in
it. Therefore it is a good idea to save your setup frequently. It is worth saving the script separately
as well, because it is saved in a suitable format for printing or off-line editing with Notepad. Note
that in both these examples the input data are referred to as InResult.DataArray. You can also write
InResult1.DataArray and InResult2.DataArray, which refer to the two input traces.
InResult.DataArray always refers to input trace 1. These remarks hold for any script that you write.

Example Waveform Function Script: Square of a waveform

' Example script to produce a waveform

This example calculates the square of

the input waveform.

OutResult.Samples = InResult.Samples ' Visible trace length + 1

' Note that a trace of nominal length 1000 comprises data numbered from

' 0 to 1001. The 1001st point is not visible, so you

' normally use points 0 to 1000,

' giving 1001 points and 1000 intervals between points.

startData = 0

endData = OutResult.Samples

LastPoint = endData - 1 ' because the last point is invisible.

ReDim newArray(OutResult.Samples) ' to store the results

unscaledData = InResult.DataArray(False)

' InResult.DataArray(False) provides

' integer data from -32768 to 32767.

' InResult.DataArray(True) provides real data

' in the same physical unit as the vertical scale of the input trace.

ScaleFactor = 1.0 / 32768 ' to make the trace fill the screen.

For i = 0 To LastPoint

newArray(i) = ScaleFactor * (unscaledData(i)) ^ 2

Next

Advertising