Teledyne LeCroy SierraNet M168 User Manual Ver.1.40 User Manual

Page 206

Advertising
background image

LeCroy Corporation

InFusion Scenarios

204

 

 

SierraNet M168 Protocol Analyzer User Manual

1

 Only shown in Action Properties dialog box when creating a sequence.

Inject General Error Invalid 10‐bit‐Error 

Code 

Injects invalid 10b code into the line (FC8 
only). 

Running Disparity 
Error

Injects a Running Disparity (RD) error into 
traffic (FC8 only. 

FEC Parity Error

Injects a FEC error into traffic.

Sync Header Error

Injects a Sync Header error into traffic.

Block Error

Injects a Block error into traffic.

Order Set Error

Injects a Order Set error into traffic.

Insert

Insert New Frame

Allows to insert a whole frame as specified 
from the list of available frames.

Symbol (66 Bit)

Allows to insert a Symbol 66 bits.

Pre‐captured Frame Allows to insert a Pre‐captured Frame 

(Ethernet only).

Insert Bytes

Allows to insert Bytes (FC only).

Ordered Set Jam

Delete

Delete an Ordered Set Jam.

Remove [Replace 
with IDLE]

Remove an Ordered Set Jam or Replace 
with another Ordered Set.

Remove [Replace 
with IDLE]

Remove an Ordered Set Jam or Replace 
with another Ordered Set (FC8 only. 

Replace with 
Another Ordered 
Set

Only replace with another Ordered Set 
(FC8 only. 

Scenario Execution Stop Scenario

Stops the current Scenario. This Action 
should be the only Action in a State as it 
has higher priority over other Actions.

Restart All 
Sequence

Restart all sequences in the Scenario.

1

Restart Current 
Sequence

Restart the sequence that contains this 
Action definition. 

1

Branch To

Destination State

Go to a state in this Sequence.

1

Trigger Output

Sends a signal out the trigger port to the 
device downstream.

Analyzer Trigger

1. The Action is to send a trigger to the 
Analyzer.
2. The trigger point in the Analyzer that 
caused the analyzer trigger action will not 
be the selected event, it will be the 
selected event with some offset.

External Trigger 
Output

The Action is to cause an external trigger 
output.

Capture 

DWORD

Capture DWORD.

Frame

Capture Frame (Ethernet only).

Action

Description

Advertising