t 0:

Keyboard Test: Tests the function of the front panel keys.

Press

to begin test. RUN: will be displayed. Press each front panel key except

to

test key. The display will indicate if the key is functional.

t 1:

Non-Volatile RAM Test: Tests CBC-1000 RAM.

Press

to begin test. The test will return PASS or FAIL. Press

to continue.

t 2:

Input Test: Tests whether CBC-1000 is accepting inputs.

Press

to begin test. Activate inputs to control.

If the input is received, a character will be displayed. “Ab” - Encoder

input, “1” - Start, “2” - Stop, “3” Continuous mode, “4” Reset. Press

to continue.

t 3:

Output Test: Used to determine whether CBC-1000 outputs are functional.

Press

to begin test. Press keys 1-6 on the front panel. The corresponding output will

turn on and latch. Use a VOM to check for a high level state on terminal strip of CBC-1000.

Press

to exit test.

t 4:

Display Test: Tests function of each LED on front panel.

Press

to begin test. Each digit of front panel display will automatically be turned on.

Check for faulty LEDs. Press

to continue.

t 5:

Program Memory Test: Tests program memory capability.

Press

to begin test. PASS or FAIL will be returned. Press

to continue.

t 6:

Date Code Test: Displays software date code.

Press

to display date code. Press

to exit. Continue.

t 7:

Serial Test: Tests connections with serial data interface module.

Press

to begin test. PASS or FAIL will be displayed. Press

to continue.

t 8:

Factory Default Settings: Returns CBC-1000 to factory settings.

Press

to return all program steps to factory default settings.

RUN

PGM