Installation, Connection diagrams, Stop wiring (e-stop) – Warner Electric CBC-1000 User Manual
Page 17
15
Warner Electric • 800-825-9050
P-275 • 819-0496
Installation
Connection Diagrams
Stop Wiring (E-Stop)
Serial
Data
Signal
Inputs
Control
Inputs
Control
Outputs
VAC
Serial
Data
Signal
Inputs
Control
Inputs
Control
Outputs
VAC
Closed: Brake On Output (terminal 16) activated
Open: Normal Operation
Note: A start input can not be executed when the switch is closed.
Stop
(E-Stop)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
RXD
-
RXD
+
TXD
-
TXD
+
+
12V
Sig
A
Sig
B
COM
Start
Stop
Continuous/Single
Reset
COM
Start
Early
W
arning
Brake
On
Zero
Speed
Zero
Speed
+
Delay
1
Zero
Speed
+
Delay
2
Aux.
Start
Batch
Complete
Hot
Neutral
Bld.
Gnd
RXD
-
RXD
+
TXD
-
TXD
+
+
12V
Sig
A
Sig
B
COM
Start
Stop
Continuous/Single
Reset
COM
Start
Early
W
arning
Brake
On
Zero
Speed
Zero
Speed
+
Delay
1
Zero
Speed
+
Delay
2
Aux.
Start
Batch
Complete
Hot
Neutral
Bld.
Gnd
CBC-1000 Open Collector Outputs:
COM
(Terminal 13)
Output
(Terminals 14 thru 21)
100 mA. sink @ 24 VDC
115
Typical
of each
output
30V
- Connect to brake Input terminal of the clutch/brake control (i.e. Terminal 6 on the CBC-700)
- Connect to clutch Input terminal of the clutch/brake control (i.e. Terminal 8 on the CBC-700)
- Connect to clutch and brake Input terminals of the clutch/brake control (i.e. Terminals 5 & 7 on the CBC-700)
Control Output (Outputs 1-8, Terminals 14-21) Wiring
Duration of output signal controlled by programming lines 10-17.