Programming – Warner Electric CBC-1000 User Manual

Page 14

Advertising
background image

12

Warner Electric • 800-825-9050

P-275 • 819-0496

LINE

DISPLAY

DESCRIPTION

OPTIONS

DEFAULT

1

b d .

Initial Braking Distance - - - -

2 5

The first brake distance used by the
CBC-1000 at power-up.

2

b d . Au E . # of Cycles Averaged 1 - 9

3

The number of cycles used for the running
average of brake distance.

3

c c .

Correction Constant

- . - - - -

0 . 5000

The scaling factor for the front panel display
(0.5000 for display in pulses).

4

d P .

Decimal Point

off, .0, .00, .000

oFF

Number of decimal places displayed. Affects
all distance values in other registers.

5

F r S t.

Front Panel Reset

on - off

on

Enables or disables front reset in the RUN
Mode.

6

P L o c .

Front Panel Lock

on - off

oFF

“On” enables and “Off” disables changing
MOV PST, E.W., and BCH PST while running.

7

C r E t .

Count Retention

on - off

on

Retains system position during power off.

8

A r S t .

AUTO Reset

on - off

oFF

Select Absolute (ON) or Incremental (OFF)
mode of operation.

9

o 1 .

Start Output

00.00 to 99.99

00 . 10

The duration (momentary or latched) of the
Start Output in seconds. For latched input,
enter all zeros or press

.

10

o 2 .

Early Warning Output 00.00 to 99.99

00 . 10

The duration (momentary or latched) of the
Early Warning output in seconds.

11

o 3 .

Brake on Output

00.00 to 99.99

00 . 10

The duration (momentary or latched) of the
Brake On output in seconds.

12

o 4 .

Zero Speed Output

00.00 to 99.99

00 . 10

The duration (momentary or latched) of the
Zero Speed output in seconds.

13

o 5 .

Zero Speed + Delay 1 00.00 to 99.99

00 . 10

The duration (momentary or latched) of the
Zero Speed + Delay 1 output in seconds.

14

o 6 .

Zero Speed + Delay 2 00.00 to 99.99

00 . 10

The duration (momentary or latched) of the
Zero Speed + Delay 2 output in seconds.

15

o 8 .

Batch Counter Reset 00.00 to 99.99

LATCH

Momentary for automatic (internal) reset or
latched for manual (operator) reset.

16

d 1 .

Delay Time 1

00.00 to 99.99

0 . 50

The delay time for Zero Speed + Delay 1
output in seconds.

17

d 2 .

Delay Time 2

00.00 to 99.99

1 . 00

The delay time for Zero Speed + Delay 2
output in seconds.

18

0 5 P .

Zero Speed Window 01, .05,.10, .25 sec. 10

The time window in seconds to determine
Zero Speed, Zero Speed equals no pulses
received within window.

19

5

Start Command

1-6

- - - - - -

Releases latched outputs at the start

Release Outputs

command. Press 1-6 on the front panel to
release or drop output.

20

L

Move Preset Release 1-6

- - - - - -

Releases latched outputs at the move preset.

Outputs

Press 1-6 on the front panel to release output
or drop output.

RESET

CLEAR

Programming

Advertising