13

Warner Electric • 800-825-9050

P-275 • 819-0496

Programming

LINE

DISPLAY

DESCRIPTION

OPTIONS

DEFAULT

21

E

Early Warning

1-6

- - - - - -

Releases latched outputs at the
Release Outputs Warning signal.
Press 1-6 on the front panel to
release output or drop output.

22

r

Reset Command

1-6

- - - - - -

Releases latched outputs at reset.

Release Outputs

Press 1-6 on the front panel to
release output or drop output.

23

b r .

Baud Rate

off, 300, 600, 900 oFF

See Serial Interface Section.

1200, 2400

24

P A r

Parity

nonE, odd, EuEn

nonE

See Serial Interface Section.

25

i d . n o .

Identification Number 0 - 99

0

Control identification number. See
Serial Interface Section. See
Troubleshooting Section on page
25 for further information on
diagnostic tests listed below.

26

t 0 .

Keyboard Test

rdy

y

Front panel keyboard test.

27

t 1 .

Non-Volatile RAM test Press

y

Non-Volatile RAM test.

28

t 2

Input Test

Ab - encoder inputs

Control input test.

1 - start

y

Refer to

2 - stop

Diagnostics

3 - cont. 4 reset

Test, Page 9

29

t 3

Output Test

1 - E

y

Control output test.

30

t 4

Display Test

Press

y

Front panel display test.

31

t 5

Program Memory Test Press

y

Control program memory test.

32

t 6

Date Code Test

Press

y

Displays Date Code of CBC-1000
software.

33

t 7

Serial Test

Press

y

Control serial test.

34

t 8

Factory Default

Press

y

Returns control to factory default

Settings