Unit Disposal

Do not place heat generating devices such as transformers and supply blocks under the island.

Heat generating devices in proximity of HTB and I/O expansion modules could result in elevated

temperatures and overheating, and can result in unexpected operation of inputs and outputs. Depending

on the I/O configuration, unintended equipment operation can occur.

Do not exceed the 450mA current limit for HTB and its expansion modules. Exceeding these limits can

result in interruption of power to the I/O. Depending on I/O configuration, unintended equipment operation

may result.

If outputs should fail, outputs may remain on or off. Where personnel and or equipment hazards exist, use

an appropriate hard-wired safety system.

When the power supply voltage is outside of the specified voltage range, one or more outputs may not

operate as expected. Use an appropriate externally-wired safety system to control and monitor the system

voltage and ensure the specified voltage range is maintained.

Turn power off before installing, removing, wiring, or maintaining.

This product is not intended for use in safety critical machine functions. Where personnel and or

equipment hazards exist, use appropriate hard-wired safety interlocks.

Do not disassemble, repair, or modify the modules.

This controller is designed for use with in an enclosure.

Install the modules according to the installation instructions on page 3-2.

Use the sensor power supply only for supplying power to sensors connected to the module.

Use an IEC60127-approved fuse on the power line and output circuit to meet voltage and current

requirements.

Recommended fuse: Littlefuse

®

5x20 mm Slo-Blo

®

218 Series.

When the product is disposed of, it should be done so according to your country's regulations for similar

types of industrial waste.