PS-B Unit Mounting

Installation Location

Mount the PS-B unit system with the mounting plates found on the housing. The
plates are designed for M5 screws.

Important mounting information

z

Environmental Characteristics. (see page 46)

z

The PS-B unit is only permitted for operation in closed rooms.

z

The PS-B unit cannot be situated in direct sunlight.

z

The vent holes must not be covered.

z

When mounting the device, adhere to the allowable Mounting angle
(see page 56
)

z

Be sure the wall or switching cabinet can support a minimum four times the total
weight of the PS-B unit.

z

When connecting certain cable types (DVI, USB, and so on), keep the flex radius
of the cable in mind.

WARNING

UNINTENDED EQUIPMENT OPERATION

Overheating can cause incorrect software behavior, therefore:

z

Do not place the PS-B unit next to other devices that might cause overheating.

z

Keep the PS-B unit away from arc-generating devices such as magnetic
switches and non-fused breakers.

z

Avoid using the PS-B unit in environments where corrosive gases are present.

z

Install the PS-B unit in a location providing a minimum clearance of 50 mm (1.96
in.) on more on the left and right sides and 100 mm (3.93 in.) or more above and
below the product from all adjacent structures and equipment.

z

Install the PS-B unit with sufficient clearance to provide for cable routing and
cable connectors.

Failure to follow these instructions can result in death, serious injury, or
equipment damage.

mm

in.

Ø

5,4 for M5 screws

Ø

0.21 for M5 screws

Ш

11

Ш

0.43

9

0.3