background image

Hardware Modifications

93

1

Battery / Load mode

2

Temperature

3

UPS battery unit

4

PS-B with integrated UPS module

5

Supply voltage +24 Vdc

Integrated UPS Module Description

The following table gives the technical data of the UPS module integrated in the PS-
B with the UPS option:

1

2

3

4

5

Features

Values

Switching Threshold Mains / Battery
Operation

15 / 13 V

Mains Failure Bridge-over Time

Max. 20 min at 150 W load

Charging Current

Max. 0.5 A

Deep Discharge Protection

At 10 V on the battery unit

Short Circuit Protection

No

Power Requirements

Max. 7.5 W

Status Indicators

Via the system monitor (see page 118)

Configuration

Via the system monitor settings (see page 122)

Advertising