15

Installation

• Determine the thickness of the board in

consideration of its strength. The mini-
mum thickness of a board is 1.6 mm
[0.06 in.] for M4 screws.

• M4 screws are not included with the PL

unit. Please prepare them by yourself.

(1) Create holes and perform the necessary

processing on the board according to the
drawing of mounting holes.

(2) Attach installation fasteners with the

accompanying four screws (M3) to the
PL unit. Pay close attention to the
direction of the fasteners. The torque
required to tighten these screws is 0.5 to
0.6N•m.

(3) Attach the PL unit to the board with the

screws (M4): First, tighten the screws
temporarily on the board; mount
installation fasteners temporarily onto
the screws; and then tighten the screws
until the PL unit is securely fixed.
The torque should be 1.0 to 1.2N•m.

Horizontal mounting

243 [9.57]

4-M4 [0.16]

258±0.3 [10.16±0.01]

270 [10.63]

35.5

[1.

4

]

220±0.

3

[8.

66±0.0

1

]

277 [

10.91]

Vertical mounting (4 slot type)

177 [6.97]

4-M4 [0.16]

192±0.3

[7.56±0.01]

204 [8.03]

35.

5

[1

.4

]

2

20±

0

.3 [8.

66±0.

01]

277

[

10.91

]

Wall mounting

35.5
[1.4]

4-M4
[0.16]

220±0.3

[8.66±0.01]

277 [10.91]

2

43 [

9

.5

7]

258

±

0.

3 [10.

16±0.01

]

270 [10

.63]

Horizontal mounting

or wall mounting

Vertical mounting

Screws

Screws

Enlarged view

Ex.: Horizontal mounting

Advertising