System set, Switch, System set switch – Proface APL3000B - Node Box PC User Manual

Page 8: Serial mode select

Advertising
background image

8

System Set Switch

Serial Mode Select Switch

Switch

No.

Description

ON

OFF

Factory

Settings

Notes

1

Internal setting

Reserved Reserved OFF

Do not change.
(Factory setting)

2

Implements the
logical inversion
operation for RAS
output

Normal
Close

Normal
Open

OFF

RAS output is a CLOSE state
when the switch and the system is
ON. When the Switch is OFF, it is
the opposite. The RAS Output
keeps Normal OPEN when the
Soft OFF state occurs or the
power turns OFF.

3

Sets up an enabled/
disabled state for the
front USB port execution
control function

*1*2

*1

Panel computer only.

*2

The Setting up an enabled/Disabled state for USB port execution control function is available for
only Windows

®

2000 and Windows

®

XP. Make sure to disable the function of the setting when

other OS is used.

Enabled Disabled ON

The front USB port is available
when the switch is ON. It is
unavailable when the switch is
OFF.

4

Internal setting

Reserved Reserved

OFF

Do not change.
(Factory setting)

5 to 8

ON

9 to 10

OFF

Switch

No.

Description

ON

OFF

RS-232C

RS-422 RS-485

1

Internal setting

Reserved

Reserved

OFF

*1

OFF

*1

OFF

*1

2

Changes COM1’s
communication method

RS-422/RS-485

RS-232C

OFF

ON

ON

3

Changes COM1’s
communication method

RS-422/RS-485

RS-232C

OFF

ON

ON

4

Changes SD (TXD)
data’s output mode

SD (TXD) data
output is controlled
via the RS (RTS)
signal.

SD (TXD) data
output is NOT
controlled via the
RS (RTS) signal.
(normally output)

OFF

ON/
OFF

ON/
OFF

*2

5

Switches the SD (TXD)
termination resistance
ON/OFF

Inserts termination
resistance of 220

between SDA and
SDB.

No termination

OFF

ON

ON/
OFF

*3

6

Switches the RD
(RXD) termination
resistance ON/OFF

Inserts termination
resistance of 220

between RDA and
RDB.

No termination

OFF

ON

ON/
OFF

*3