Internal switches of the control box – Proface APL3000B - Node Box PC User Manual

Page 7

Advertising
background image

7

• Make sure to turn off the power supply before using the switches. Adjusting the

switches while power is supplied may cause errors.

1.

Internal switches of the control box

SW5

1 10

1 10

SW4

SW1

SW2

SW3

OFF

ON

ON

OFF

Bottom face of the control box

(CI)RI

5V

Switch

Location

Switch Name

Com-

patible

I/F

Factory

Settings

Description

SW1

System Set
Switch

See

System Set

Switch

10-point DIP switch. For System Set
Switch and the factory settings
details, see

System Set Switch.

SW2

Serial Mode
Select Switch

COM1

All OFF
(RS-232C)

10-point DIP switch. Designates
COM1 communication settings.
For Serial Mode Select Switch
details, see

Serial Mode Select

Switch.

SW3

CI(RI)/+5V
Changeover
Switch

COM2 CI(RI)

Not available on the built-in battery
unit version.

SW4

CI(RI)/+5V
Changeover
Switch

COM1 CI(RI)

Changes # 9 pin (CI(RI) / +5V).

SW5

*1

DVI Cable
Selection
Switch

Side without the
symbol

Q

(FP-DV01-100 is
not supported)

Toggles between supporting and not
supporting the FP-DV01-100 [DVI-D
cable (10m)], a Pro-face FP3000
Series option.
For details, see

DVI Cable Selection Switch.

*1 .PL-3000B series only.