DVI Cable Selection Switch

When connecting Pro-face FP3000 Series to PL-3000B series unit, use the Pro-face DVI-D
cable (10m) FP-DV01-100. (Other 10m DVI cables are not supported)

When using FP-DV01-100, change DVI Cable Selection Switch (SW5) settings.

7

Switches the shorting
of SDA and RDA ON or
OFF

Shorts SDA and
RDA
(RS-485 mode)

No shorting
(RS-422 mode)

OFF

OFF

ON

8

Switches the shorting
of SDB and RDB ON or
OFF

Shorts SDB and
RDB
(RS-485 mode)

No shorting
(RS-422 mode)

OFF

OFF

ON

9

RS (RTS) Automatic
control mode
(enabled only when
RS-485 mode)

The data is
automatically
controlled via the
RS (RTS) signal.

The data is not
automatically
controlled via the
RS (RTS) signal.

OFF

OFF

ON/
OFF

*2

10

OFF

OFF

ON/
OFF

*2

Serial Mode Select Switches (SW4 to SW10) operate as shown in the circuit diagram below.

*1 Be sure to leave these settings OFF.

*2 Set switches number 9 and 10 to ON when the SD (TXD) output driver is automatically controlled

with RS (RTS). Set switch number 4 to OFF.
Set switches number 9 and 10 to OFF when the SD (TXD) output driver is controlled with the RS
(RTS) signal. Set switch number 4 to ON.

*3 If you use the termination resistance, base your settings on the connection specifications.

Switch

No.

Description

ON

OFF

RS-232C

RS-422 RS-485

*2

RT(RTS) Automatic
control

Factory Setting

For FP-DV01-100