I/o device configuration – Proface APL3000B - Node Box PC User Manual

Page 51

Advertising
background image

PL3000 Series Reference Manual

2-20

„ I/O Device Configuration

Specifies the address and interrupt level of the I/O ports. Point the cursor to the [I/O Device Configuration] on

the [Integrated Device Configration] screen and press the [Enter] Key, so that the following screen will be

displayed.

COM Port 1, 2, 3, 4

Specifies whether to use the COM port.

[Enabled]

Uses the COM port.

[Disabled]

Does not use the COM port.

Base I/O Address

Specifies the base I/O address of the COM port. The base I/O address must be unique among the COM ports.

When [COM Port] is [Disabled], this option is not displayed.

[3F8] (Factory default setting for COM1)

The base I/O address is set to 03F8h-03FF.

[2F8] (Factory default setting for COM2)

The base I/O address is set to 02F8h-02FF.

[3E8] (Factory default setting for COM3)

The base I/O address is set to 03E8h-03EF.

[2E8] (Factory default setting for COM4)

The base I/O address is set to 02E8h-02EF.

Interrupt

Specifies the interrupt No. of the COM port. The interrupt No. must be unique among the COM ports. When

[COM Port] is [Disabled], this option is not displayed.

[IRQ3] (Factory default setting for COM2) The interrupt No. is set to 3.

[IRQ4] (Factory default setting for COM1) The interrupt No. is set to 4.

[IRQ10] (Factory default setting for COM4) The interrupt No. is set to 10.

[IRQ11] (Factory default setting for COM3) The interrupt No. is set to 11.