PS-3710A/PS-3711A Series Hardware Manual

2-28

COM2

COM2 can be changed to either RS-232C, RS-422 or RS-485. (The factory setting is RS-232C.) To change

this setting, open the PS-A unit's rear cover and set slide switch on the circuit board to the desired position.

SEE

Switches (page 2-30)

• Be sure to confirm what settings will be used by the other device and set the slide

switches accordingly. Failure to do so can result in a unit malfunction or damage.

• Whenever changing the PS-A switches, be sure to first turn the PS-A's power

supply OFF. Failure to do so can cause a PS-A malfunction.

Pin Arrangement

Pin No.

RS-232C

Signal Name

Direction

Meaning

1

CD

Input

Carrier Detect

2

RD(RXD)

Input

Receive Data

3

SD(TXD)

Output

Send Data

4

ER(DTR)

Output

Data Terminal Ready

5

GND

-

Signal Ground (SG)

6

DR(DSR)

Input

Data Set Ready

7

RS(RTS)

Output

Request to Send

8

CS(CTS)

Input

Clear to Send

9

CI(RI)

Input

Called status display

FG

FG

-

Frame Ground
(Common with SG)

Pin No.

RS-422

Signal Name

Direction

Meaning

1

RDA

Input

Receive Data A (+)

2

RDB

Input

Receive Data B (-)

3

SDA

Output

Send Data A (+)

4

NC

-

No Connection

5

GND

-

Signal Ground (SG)

6

NC

-

No Connection

7

SDB

Output

Send Data B (-)

8

NC

-

No Connection

9

NC

-

No Connection

FG

FG

-

Frame Ground (Common with SG)

9

6

5

1

(PS-A side)

Advertising