Chapter 2 Specifications

2-31

Switch

No.

Description

ON

OFF

Factory

Settings

Notes

1

Disable/enable Detecting the
middle point during touching
two points simultaneously.

*1

*1

When two points are pushed simultaneously, it is considered that middle point between the two

points is touched according to the nature of the analog resistive touch panel.

If a switch or other part is located on the middle point, it will be detected and may be operated

without any touches. To prevent such a switch from malfunction during two points are pushed

simultaneously, set Switch Number 1 to ON.

Even, drug control could not be operated very smoothly.

Disabled

Enabled

OFF

The middle point is not
considered to be touched
when the SW is ON. It is
considered to be touched
when the SW is OFF.

2

Changes PIO/DMA of CF Card.

PIO+DMA

PIO

ON

3

Changes PIO/DMA of CF Card.

PIO+DMA

PIO

ON

4

Disable/enable Hardware
Reset Switch.

Disabled

Enabled

OFF

The hardware switch is
unavailable when the SW
is ON. But, it is available to
enter switch from the Soft
OFF

*2

state.

*2

The Soft OFF refers to the state that Windows

®

has been shut down and the power is provided

only for the electric circuit to boot system. This Soft OFF State is different from what is System

Standby set by Windows

®

.

5

Able to change a Master/Slave
setting for CF Card slot.

Master

Slave

OFF

*3

*3

When built in Pro-face's Windows

®

XP Embedded, the factory setting is ON.

6

Disable/enable Access to the
Front USB port.

*4

*4

The Setting up an enabled/Disabled state for USB port execution control function is available for

only Windows

®

2000 and Windows

®

XP. Make sure to disable the function of the setting when

other OS used.

Enabled

Disabled

ON

The front USB port is
available when the SW is
ON. It is unavailable when
the SW is OFF.

7

Used for the system.

Reserved

Reserved

OFF

8

Used for the system.

Reserved

Reserved

OFF

As for PS3711A-T42/
PS3711A-T42-24V, the
factory setting is ON.

9

Implements the logical
inversion operation for RAS
output.

Normal
Close

Normal
Open

OFF

RAS output is a CLOSE
state when the SW and the
system is ON. When the
SW is OFF, it is the
opposite. The RAS Output
keeps Normal OPEN when
the Soft OFF

*2

state

occurs or the power turns
OFF.

10

Used for the system.

Reserved

Reserved

OFF

Table 1) System Set Switches