Component names, Component names -1 – Yokogawa EJX438B User Manual

Page 18

Advertising
background image

<3. Component Names>

3-1

IM 01C27H01-01EN

3. Component Names

EJX118B

* See below

for details

EJX438B

F0301.ai

Transmitter

section *

Diaphragm seal

with flushing connection ring

Flushing

connection ring

Drain/vent plug

Cover flange

Diaphragm seal

(high pressure side)

Diaphragm seal

(low pressure side)

Capillary tube

Cover flange

Pressure-

detector section

Diaphragm seal

Pressure-

detector section

Transmitter

section *

* See below

for details

Figure 3.1

Component Names (External View of Flush type)

Pressure-detector section

Antenna (Note 3)

F0302.ai

YES

(Note 2)

(Write disabled)

NO

(Write enabled)

Zero-adjustment screw

Ground terminal

RF assembly

CPU assembly

Cover flange

Bolt

Transmitter section

Amplifier cover

Mounting screw

Integral indicator

Hardware write protection switch (WR)

Write Protection

Write Protection

Switch Position

(Note 1)

H

L

E

D

H

L

E

D

Slide switch

E WR

D

Not in use

Write protection

switch

Note 1: Write Protection is set by sliding the hard write protection switch (WR) shown in figure. The hardware write protection switch is

set to the E side (Write enable) for delivery. Set an unused switch to H side.

Note 2: When the switch is D side (write protection setting), provisioning is acceptable. For details of provisioning, refer to section 7.4

“Connecting to Field Wireless Network”.

Note 3: The detachable antenna is applied when the amplifier housing code 7 or 8 is specified.

Figure 3.2

Component Names (Details of Transmitter section)

Table 3.1

Display Symbol

Display Symbol

Meaning of Display Symbol

Display mode is ‘square root’. (Display is not lit when ‘linear’ mode.)

The output signal being zero-adjusted is increasing.

The output signal being zero-adjusted is decreasing.
Write protect function is enabled.

Advertising
This manual is related to the following products: