4.4 Mounting the Flushing

Connection Ring

4.4.1 Mounting to Pressure Detector

Section

The flushing connection ring is mounted to the

pressure detector section as shown in Figure 4.7.

At the factory shipment, the flushing connection

ring is already assembled and attached to process

detector section.

Ring holder

Spiral gasket

F0407.ai

View from pressure detector section

Groove for installing

spiral gasket

Pressure-detector section

Drain/vent plug

Ring

Figure 4.7

Mounting to Pressure Detector Section

(1) Mount the ring holder on the ring and loosely

tighten the mounting screws.

(2) Place the spiral gasket in the ring groove. With

the ring correctly aligned and flush with the face

of the pressure detector, securely tighten each

ring holder’s mounting screws.

(3) Position the ring so that the drain/vent plugs are

aligned straight up and down.

4.4.2 Mounting to Process Flange

Tighten the bolts to completely close the gap

between the ring and the pressure detector section.

The mating flange, gasket, stud bolts and nuts are

to procured by the customer.