<4. Installation>

4-1

IM 01C27H01-01EN

4. Installation

4.1 Precautions

Before installing the transmitter, read the cautionary

notes in section 2.4, “Selecting the Installation

Location.” For additional information on the

ambient conditions allowed at the installation

location, refer to subsection 10.1 “Standard

Specifications.”

NOTE

To connect this transmitter to the field wireless

network, information on connecting to field

wireless devices needs to be set beforehand.

Refer to 6.4 “Connecting to the Field Wireless

Network.”

IMPORTANT

• When welding piping during construction,

take care not to allow welding currents to

flow through the transmitter.

• Do not step on this instrument after

installation.

• For the EJX438B, there is a small hole in the

low pressure side cover flange that is used to

measure the atmospheric pressure.

The hole must not face upward. See section

10.4, “Dimensions,” for the location of the

hole.

• Never loosen the four bolts securing the

cover flanges (Refer to figure 3.2.) If the seal

liquid leaks, the transmitter cannot be used.

4.2 Mounting the Diaphragm

Seals

Mount the diaphragm seals using the flanges as

shown in Figure 4.1. Figure 4.2 and Figure 4.3

shows how to mount the diaphragm seals on a

tank. The mating flange, gasket, bolts and nuts are

to be procured by the customer.

Nut

Flange

Diaphragm

Ød

Gasket

F0401.ai

Bolt

The product is shipped with

these parts assembled.

Correctly install the diaphragm seals on

the high and low pressure sides of the

process (The label on each diaphragm

seal is marked

HIGH or LOW.)

Figure 4.1

Mounting the Diaphragm Seals

IMPORTANT

Please use a gasket with an inside diameter

(ød) that is greater than the diameter of the

diaphragm seal. If a gasket with a smaller

inside diameter is used, the diaphragm may not

function correctly. (Refer to Subsection 10.4

‘Dimensions’)

Advertising