7 changing the direction of integral indicator, 8 changing the direction of the antenna, Changing the direction of integral indicator -6 – Yokogawa EJX438B User Manual

Page 24: Changing the direction of the antenna -6, Warning, Important

Advertising
background image

<4. Installation>

4-6

IM 01C27H01-01EN

The transmitter section can be rotated

approximately 360° (180° to either direction or

360° to one direction from the original position at

shipment, depending on the configuration of the

instrument.) It can be fixed at any angle within

above range.

1) Remove the five setscrews that fasten the

transmitter section and capsule assembly,

using the Allen wrench.

2) Rotate the transmitter section slowly and stop it

at designated position.

3) Tighten the five setscrews to a torque of 1.5

N·m.

IMPORTANT

Do not rotate the transmitter section more than

the above limit.

F0410.ai

Transmitter section

Rotate 180°segments

Pressure-detector section

Figure 4.10 Rotating Transmitter Section

4.7 Changing the Direction of

Integral Indicator

WARNING

Intrinsic safe type transmitters must be, as a

rule, remove a battery pack in non-hazardous

area before open/close the Amplifier Cover or

disassembling and reassembling the Integral

Indicator.

An integral indicator can be rotated in four positions

at 90°. Follow the instructions in section 8.4.1 for

removing and attaching the integral indicator.

4.8 Changing the direction of

the antenna

Adjust the direction of the antenna to be in the

upright position. Figure 4.11 shows factory setup

antenna position. If the transmitter is installed to

vertical impulse piping, follow the procedure below

and change the antenna position.

1) Loosen the two mounting screws at the bottom

of the antenna by using a 2.5 mm Allen wrench

(see Figure 4.11).

The screws might come off and be lost if

loosened too much; loosen the screws by about

three rotations.

2) Press forward and down 90 degrees by rotating

the axis at the bottom of the antenna.

3) Tighten the two screws to a torque of 1.5 N·m

by using a torque wrench. When doing this, be

careful not leave a gap between the antenna

and housing.

F0411.ai

Figure 4.11 Mounting Screw Position

F0412.ai

Figure 4.12 Adjusting Antenna Position

Advertising
This manual is related to the following products: