Yokogawa EJX438B User Manual

Page 93

Advertising
background image

<10. General Specifications>

10-7

IM 01C27H01-01E

*6:

In case of wetted parts material code HW (Hastelloy C), TW (Tantalum), and UW (Titanium) for 2-inch pressure flange, specify

capillary length from 1 to 5 m.

*7:

Not applicable for flashing connection ring code 1 and 2.

*8:

Not applicable for gasket contact surface code 1.

*9:

Hastelloy C-276 or N10276.

*10: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of

inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant

facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid

can contaminate the user’s process fluids.

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite,

and high-temperature steam (150˚C [302˚F] or above). Contact Yokogawa for detailed information of the wetted parts material.

The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of 316

SST material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details

Advertising
This manual is related to the following products: