Notes on handling, 1 check the model name and configuration, 2 transport – Yokogawa Wireless Temperature Transmitter YTA510 User Manual

Page 9: 3 storage, Notes on handling -1, Check the model name and configuration -1, Transport -1, Storage -1

Advertising
background image

<2. Notes on Handling>

2-1

IM 01C50E01-01EN

2. Notes on Handling

The YTA temperature transmitter is fully factory-

tested upon shipment. When the YTA is delivered,

check the appearance for damage, and also

check that the transmitter mounting parts shown

in Figure 2.1 are included with your shipment. If

“No Mounting Bracket” is indicated, no transmitter

mounting bracket is included.

U-bolt nut

Horizontal pipe

mounting bracket

Vertical pipe

mounting bracket

Bracket

fastening bolt

Spring washer

Bracket

fastening nut

Transmitter

fastening bolt

Spring washer

Transmitter

fastening bolt

Spring washer

U-bolt

U-bolt

F0201.ai

The antenna is a detachable type

when Amplifier housing code 8 is

selected, and no antenna is provided

for Amplifier housing code 9.

Antenna

Figure 2.1

Transmitter Mounting Hardware

2.1 Check the Model Name and

configuration

The model name and configuration are indicated

on the nameplate. Verify that the configuration

indicated in the “Model and Suffix Code” in Chapter

10 is in compliance with the specifications written

on the order sheet.

: Refer to USER'S MANUAL.

Made in Japan

TOKYO 180-8750 JAPAN

MODEL

SUFFIX

SUPPLY

OUTPUT

mA DC

V DC

STYLE

CAL

RNG

NO.

F0202.ai

TEMPERATURE

TRANSMITTER

Figure 2.2

Name Plate

2.2 Transport

To prevent damage while in transit, leave the

transmitter in the original shipping container until it

reaches the installation site.

2.3 Storage

When an extended storage period is expected,

observe the following precautions.
1. Choose a storage location that satisfies the

following requirements.

• A location that is not exposed to rain or water.

• A location subject to a minimum of vibration or

impact.

• The following temperature and humidity range

is recommended. Ordinary temperature and

humidity (25°C, 65%) are preferable.

Temperature:

–40 to 85°C

–30 to 80°C (LCD visible

range)

Humidity:

5 to 100% RH (at 40°C)

2. If at all possible, store the transmitter in

factory-shipped condition, that is, in the original

shipping container.

3. Preferably remove the batteries for storage. For

maximum battery life, the storage temperature

should not exceed 30°C

Advertising