Yokogawa µR10000 User Manual

Page 238

Advertising
background image

IM 04P01B01-01E

12-10

Name

Display Example

Description

1CH digital display

2CH digital display

4CH digital display

6CH digital display

(Dot model)

4CH bargraph display

(Pen model)

1CH digital + 1CH bargraph

display

2CH digital + 2CH bargraph

display

6CH bargraph display

(Dot model)

Flag display

Channel alarm status display

Time/Chart speed display

1CH digital + 4CH bargraph

display (Pen model)

Channel number

Alarm

Measured

value

Unit

Measurement channel

Measurement channel

Measurement channel

Measurement channel

Measurement channel

Computation channel

Computation channel

Computation channel

Computation channel

Computation channel

Channel number (1 digit), alarm (1 digit),

measured value (7 digits), unit (6 digits)

Channel number (1 digit), alarm (1 digit),

computed value (9 digits), unit (6 digits)

Channel number (1 digit), alarm (1 digit),

measured value (7 digits), unit (6 digits)

Channel number (1 digit), alarm (1 digit),

computed value (9 digits), unit (6 digits)

Channel number (1 digit), alarm (1 digit),

measured value (6 digits)

Bar graph, scale

Channel number (1 digit), alarm (1 digit),

computed value (6 digits)

Bar graph, scale

Displayable values are –19999 to 99999 and a

decimal. If this range is exceeded, the value

is displayed as“–####” or “+####.”

Channel number (1 digit), alarm (1 digit),

measured value (6 digits)

Bar graph, scale

Bar graph, scale

Flag, scale

Displays the date/time on the left and chart

speed on the right.

Alarm is not set.

Alarm is not occurring.

Channel number Alarm is occurring.

Measured value (5 or 6 digits)

Channel number (1 digit), alarm (1 digit),

measured value (6 digits), unit (3 digits)

Bar graph, scale, alarm (bar graph)

Value and bar graph of the same channel.

Channel number (1 digit), alarm (1 digit),

computed value (6 digits)

Displayable values are –19999 to 99999 and

a decimal. If this range is exceeded, the value

is displayed as“–####” or “+####.”

Channel number (1 digit), alarm (1 digit),

measured value (6 digits), unit (3 digits)

Displays using 5 х 7 dots when the unit

exceeds 3 digits.

Channel number (1 digit), alarm (1 digit),

computed value (9 digits)

AH9999999.9

1H3000.0ABC

1H3000.0ABC

1H-1999.9ABCDEF

2L 2000.0PQRSTU

AH-999999.9ABCDEF

BL9999999.9PQRSTU

999.9 999.9 999.9

999.9 999.9 999.9

AH-1999.9 BH-1999.9

CH9999.9 DH9999.9

1H3000.0 1H3000.0

3H3000.0 4H3000.0

AH-1999.9 BH9999.9

1H-1999.9ABCDEF

Sep.21.2004 1200

11:26:37 mm/h

AH9999999.9ABCDEF

1H3000.0 2L-999.9

12.4 Dsplay Functon Specfcatons