Pro-Cut PFM 9.2 User Manual

Page 18

Advertising
background image

PG /

Ø34

800.543.6618

WWW.PROCUTUSA.COM

PG /

Ø35

TROUBLESHOOTING

START BUTTON

RESET BUTTON

CALIBRATION BUTTON

Higher binary codes will
yield a wider acceptance
range. Lower binary
codes result in tighter
acceptance bands.

NOTE

All 9.2DRO DRO machines are calibrated to a value of 1.0 from the factory. This value should give
the best performance and should only be changed at the direction of a qualified Pro-Cut service tech.

TROUBLE SHOOTING

HOW TO RAISE OR LOWER THE ACCEPTANCE NUMBER

With the brake lathe plugged in

but not turning, push RESET and release, and wait for the READY TO START

light to be illuminated

With the READY light illuminated, press and hold the CALIBRATION button (located just below the lights)
until the ADJUSTING light illuminates, then release the CALIBRATION button.

Now the machine is displaying the acceptance number. Generally this should be 1.0.

To raise the acceptance number (loosen the calibration), press the START button once. To lower the accep-
tance number (tighten the calibration), press the CALIBRATION button once. The acceptance number will
change in increments of two. After raising or lowering, hit the RESET button to save the change.

Once you have raised or lowered the acceptance number by two and hit RESET, test the machine to ensure
that the problem has been solved. You may need to repeat the procedure once or twice to fully solve the
problem.

If you have any difficulty or questions about executing this procedure, call Pro-Cut.