Application – MAHLE RTI RHS700 User Manual

Page 3

Advertising
background image

- 1.1 -



Application



C:\RHS Computer Files\Instructions\RHS\GB\645-40\0009A-01.doc 1997.03.26
RHS 700

Your new RHS 700 station represents the latest in equipment for servicing air-
conditioning units (A/C units). The station is designed for refrigerants R12 and
R134a. It can, and must, only be used for one of these refrigerants.

RHS 700 is a test, recovery/recycling-(draining/cleaning), evacuation, oil/ref-
rigerant charging station and is thus able to perform a total process cycle in
servicing A/C units for the automobile industry.

The recycling process is designed to follow SAE-standards J1989 and J2099 on
recycled refrigerant for A/C units.

Process operations - from test to charging - are performed by operating four
different process switches and two shut-off valves. This reduces the risk of error
operation to a minimum.

Constant monitoring ensures that the automatic process sequence does occur
correctly. Safety devices are built into the station to stop operation and indicate
faults in processes, e.g. excessively high pressure, overcharging of charging
cylinder.

During the recycling process a small quantity of oil is drained from the A/C unit.
On completion of the recovery process this quantity can be drained into a
measuring beaker. The same quantity of new oil must be filled into the A/C unit.
Refer to the A/C unit instructions and use only the type of oil specified.

The filter driers have a very high capacity (200 kg) and are easy to replace during
servicing.

A system built into the station ensures that non-condensable gases are automa-
tically blown off and that the discharge of refrigerant to the atmosphere is kept to
a minimum.

Before using RHS 700, read these instructions carefully to ensure that the pro-
cesses are performed correctly.