Environmental requirements, Table 6 – Brocade VDX 8770-8 Hardware Reference Manual User Manual

Page 37

Advertising
background image

Brocade VDX 8770-8 Hardware Reference Manual

17

53-1002564-04

Preparing for the Brocade VDX 8770-8 installation

2

Environmental requirements

DANGER

Do not install the device in an environment where the operating ambient temperature might
exceed 40°C (104°F).

Table 6

lists the environmental operating ranges for the Brocade VDX 8770-8. The requirements for

non-operating conditions are also provided for acceptable storage and transportation
environments.

NOTE

The 0

to 40

C (32

to 104

F) range applies to the ambient air temperature at the air intake vents

on the port side of the Brocade VDX 8770-8.

The temperature inside the Brocade VDX 8770-8 can be up to 90°C (194

F) for some modules

during operation. Brocade recommends that the internal temperature not exceed 75°C (167

F).

Cooling policy is based on a combination of ambient temperature and measured temperature on the
modules. Various combinations will result in an increase in fan speed to create more cooling in the
switch.
If a component approaches a critical temperature that will trigger a module shutdown, there will be
a WARNING message in the RASlog, followed by a CRITICAL message saying that the module will
shut down in two minutes.
Use the show environment command to view temperature status.

TABLE 6

Environmental requirements

Condition

Acceptable range during operation

Acceptable range during non-operation

Ambient temperature

0

to 40

C (32

to 104

F) outside

switch

-25

to +70

C (-13

to 158

F) outside

switch

Humidity

5% to 90% RH noncondensing, at 40

 C

(104

F), with maximum gradient of 10%

per hour

10% to 90% RH noncondensing, at 70

C

(158

F)

Altitude

0 to 3 km (10,000 ft.) above sea level

0 to 12 km (40,000 ft.) above sea level

Shock

20G, 6 ms duration, half-sine wave

33G, 11 ms duration, half-sine wave

Vibration

0.5G p-p, 5-500 Hz at 1.0 octave/minute

2.0G p-p, 5-500 Hz at 1.0 octave/minute

Airflow

Maximum: 1250 cu ft/min. (2124 cu
m/hr)
Nominal: 325 cu ft/min. (552 cu m/hr)

None required

Maximum heat
dissipation

Up to 11500W or 39,250 BTU/hr

Not applicable

Advertising