Management module removal and replacement, Time and items required, Faulty management module indicators – Brocade VDX 8770-8 Hardware Reference Manual User Manual

Page 88: Recording critical brocade vdx 8770-8 information, Removing a management module

Advertising
background image

68

Brocade VDX 8770-8 Hardware Reference Manual

53-1002564-04

Management module removal and replacement

5

Management module removal and replacement

This section describes how to remove and replace a management module (MM). Each Brocade VDX
8770-8 chassis can have one or two management modules. They reside in slots M1 and M2. There
must be at least one MM installed for the chassis to operate.

Time and items required

The replacement procedure for the MM takes approximately 30 minutes. The following items are
required for the MM replacement:

ESD grounding strap

Workstation computer

Serial cable

IP address of an FTP server for backing up the Brocade VDX 8770-8 configuration

#2 Phillips screwdriver

Replacement management module

Faulty management module indicators

Confirm that you need to replace the management module. The following events might indicate
that a management module is faulty:

The status LED on the management module is lit steady amber, or the power LED is not lit.

The management module does not respond to Telnet commands, or the serial console is not
available.

The show mm command does not show that the management module is enabled.

Additional information from the show mm command indicates a problem.

The clock is inaccurate, or the management module does not boot up or shut down normally.

For more information about error messages, refer to the Network OS Message Reference.

Recording critical Brocade VDX 8770-8 information

Back up the chassis configuration before you replace a management module. Refer to

“Backing up

the configuration”

on page 39 for backup information.

Removing a management module

For this procedure, please refer to

“ESD precautions”

and

Figure 21

.

The chassis continues to operate while a management module is being replaced if the redundant
management module is active and a failover has already occurred.

Complete the following steps to remove a management module.

1. Remove any cables connected to the module.

2. Unscrew the captive screws from both ejectors using the Phillips screwdriver.

Advertising