802.1ag over PBB OAM

11

B-VLAN MAs (

Figure 53

)

B-VLAN MAs manage the B-VLANs within a single PBBN.

The scope of these 802.1ag frames is the PBB network only. These frames do not leave the
PBB network.

These CFM frames are only visible within the PBBN where the B-TAG is being processed.

I-SID MAs (

Figure 53

)

Backbone service instance CFM frames are only visible within the PBBN where the I-TAG is
being processed.

PBB LAN Link Segment MAs (

Figure 53

)

PBB LAN link MAs optionally manage links within a PBBN.

FIGURE 53

PBB MA Frames

Types of MEPs and MIPs

Associated with the MAs described in the previous section, there are MEPs and MIPs. Support is
provided for the following types of MIPs and MEPs on the appropriate interfaces:

MIPs and up/down MEPs for C-VIDs: Where C-Tags are processed

MIPs and up/down MEPs for S-VIDs: Where S-Tags are processed

Up/down MEPs for I-SIDs: Where I-Tags are processed

MIPs and up/down MEPs for B-VIDs: Where B-Tags are processed

Down MEPs for Link MAs

Hierarchical Fault Detection Operation

Ethernet OAM uses a hierarchical fault detection scheme.

Customer scope: Uses C-VLAN MA and Link MA

PB scope: Uses S-VLAN MA and Link MA

PBB scope: Uses B-VLAN MA, I-SID MA, and Link MA