Configuring BFD for the specified protocol

25

TABLE 129

Display of BFD neighbor detail information

This field...

Displays...

Total number of Neighbor entries

Total number of BFD sessions.

NeighborAddress

IPv4 or IPv6 address of the remote peer.

State

The current state of the BFD session:

Up
Down
A.DOWN – The administrative down state.
INIT – The Init state.
UNKNOWN – The current state is unknown.

Interface

The logical port on which the peer is known.

Holddown

The interval in microseconds after which the session will transition to
the down state if no message is received.

Interval

The interval in microseconds at which the local device sends BFD
messages to the remote peer.

R/H

Heard from remote, values: Y or N where Y stand for Yes and N stand for
No; H- Single hop/Multihop Values are S and M where S stand for Single
Hop and M stand for MultiHop.

Registered Protocols

Specifies which protocols are registered to use BFD on this port.

Local:

Disc

Value of the local discriminator field in the BFD Control Message as
used by the local device in the last message sent.

Diag

Value of the diagnostic field in the BFD Control Message as used by the
local device in the last message sent.

Demand

Value of the demand bit in the BFD Control Message as used by the local
device in the last message sent.

Poll

Value of the poll bit in the BFD Control Message as used by the local
device in the last message sent.

MinTxInterval

The interval in microseconds during which the device will send a BFD
message from this local neighbor port to the peer.

MinRxInterval

The interval in microseconds that the neighbor device waits to receive a
BFD message from the peer on this local port.

Multiplier

The number of times the neighbor device will wait for the MinRxInterval
time on this port before it determines the peer device is non-operational.

Remote:

Disc

Value of the local discriminator field in the BFD Control Message as
received in the last message sent by the remote peer.

Diag

Value of the diagnostic field in the BFD Control Message as received in
the last message sent by the remote peer.

Demand

Value of the demand bit in the BFD Control Message as received in the
last message sent by the remote peer.

Poll

Value of the poll bit in the BFD Control Message as received in the last
message sent by the remote peer.

MinTxInterval

The interval in milliseconds during which the device will send a BFD
message from the remote neighbor port to the peer.