Switch Specifications (Continued)

TABLE 3

Brocade 300

Weight

4.2 kg (9.3 lbs)

Facility requirements

The following table provides the facilities requirements that must be met for the Brocade 300.

Facility Requirements

TABLE 4

Type

Requirements

Electrical

• Primary AC input 100-240 VAC, 2.0A, 47-63 Hz; switch autosenses input voltage
• Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on the

switch nameplate

• Circuit protected by a circuit breaker and grounded in accordance with local electrical codes

Refer to

Power supply specifications

on page 34 for complete power supply specifications.

Thermal

• A minimum air flow of 39.1 cubic meters/hour (23 cubic ft/min.) available in the immediate

vicinity of the switch

• Ambient air temperature not exceeding 40 ° C (104 ° F) while the switch is operating

Rack installation • One unit (1U) in a 48.3 cm (19-inches) rack

• All equipment in rack grounded through a reliable branch circuit connection
• Additional weight of switch not to exceed the rack's weight limits
• Rack secured to ensure stability in case of unexpected movement

Power supply specifications

The power supply is universal and capable of functioning worldwide without using voltage jumpers or
switches. It meets IEC 61000-4-5 surge voltage requirements and is autoranging in terms of
accommodating input voltages and line frequencies. The power supply has its own built-in fan for
cooling, pushing the air toward the port side of the switch. The power supply is not removable.

Brocade 300 Power Supply Specifications

TABLE 5

Specification

Value

Inlet

C13

Maximum output from the power supply

75 watts

System power consumption

48 watts nominal, 57 watts maximum

Facility requirements