Environmental requirements – Brocade 300 Hardware Reference Manual User Manual

Page 35

Advertising
background image

Brocade 300 Power Supply Specifications (Continued)

TABLE 5

Specification

Value

Input voltage

85 - 264 VAC, universal

Input line frequency

47 - 63 Hz

BTU rating

277 BTU/hr

Inrush current

21.5 Amps at 240 Vac Cold Start

Environmental requirements

The following table lists the acceptable environment for both operating and nonoperating (such as
during transportation or storage) conditions.

Environmental Requirements

TABLE 6

Condition

Acceptable Range During Operation

Acceptable Range During Non-
Operation

Ambient Temperature -10° to +40° C (14° to 104° F)

-25° to 70° C (-13° to 158° F)

Humidity

10% to 85% RH noncondensing, at 40°C, with
maximum gradient of 10% per hour

10% to 90% RH noncondensing, at 70°
C

Altitude

0 to 3 km (9,842 ft) above sea level

0 to 12 km (39,370 ft) above sea level

Shock

20 G, 6 ms duration, half sine wave

33 G, 11 ms duration, half sine

Vibration

0.5 G, 5-500 Hz

2.0 G, 5-500 Hz

Air flow

High speed: 39.1 CMH (23 CFM)

Low speed: 30.6 CMH (18 CFM)

None required

NOTE
The -10° to 40° Celsius range applies to the ambient air temperature at the air intake vents on the non-
port side of the switch. The temperature inside the switch can be up to 80° Celsius during switch
operation. If the internal temperature range exceeds the operating ranges of the components, the LEDs,
error messages, and Fabric Watch alerts indicate a problem. Enter the tempShow or Fabric Watch
commands to view temperature status.

Environmental requirements

Brocade 300 Hardware Reference Manual

35

53-1000862-06