Functional

Description

UTU-701 and ETU-751 List 1

August 9, 2002

21

Table 13

summarizes the equivalent loopbacks for two different activation methods:

LTU and NTU LOC and REM buttons

console screen Test menus (see

“Testing”

on

page 60

for loopback operation from the Test menus)

BER T

ESTING

The HDSL units provide a mechanism for validating circuit integrity utilizing a pseudorandom bit sequence
(PRBS) generator and BER meter internal to the LTU unit. This diagnostic test disrupts the normal flow of
payload traffic, and requires the presence of a Network NTU-I/F loopback or an external physical loopback at the
NTU interface connector. The test is run at the selected HDSL Payload Rate (see

Table 18 on page 38

). BER

results are accumulated continuously and updated on the console screen at intervals of approximately 16 seconds.

The PRBS data pattern is always generated at the LTU toward the HDSL channel, and the BER is always
measured at the LTU based on data received from the HDSL channel. The test may be initiated and stopped from
the Test menu at either the LTU or NTU console screen.

Table 13.

Loopback Equivalents

Front Panel

Console Screen Test Menu

Loopback mode

Loopback Position

LTU LOC button

NETWORK

(a)

LTU-HDSL

LTU REM button

NETWORK

NTU-I/F

NETWORK

LTU-I/F

NTU LOC button

CUSTOMER

(b)

NTU-HDSL

NTU REM button

CUSTOMER

LTU-I/F

CUSTOMER

NTU-I/F

(a)

Activated from console screen Test menu at LTU.

(b) Activated from console screen Test menu at NTU.

The BER test must be stopped before leaving the test menu to restore normal
payload transmission. Typing

while the BER test is in progress causes the

following message to display:

BER Test in Progress. Must STOP

before leaving screen

.”

ESC