Alcatel-Lucent Omni 6624 User Manual

Page 72

Advertising
background image

Console Port

OmniSwitch 6600 Series Chassis and Hardware Components

page 2-52

OmniSwitch 6600 Series Hardware Users Guide

April 2004

4

To change the data bits (i.e., word size) value, enter boot serialwordsize, followed by the number of

data bits. Options include 7 and 8 (default). For example:

Boot > boot serialwordsize 7

5

To change the stop bits value, enter boot serialstopbits, followed by the number of stop bits. Options

include 1 (default) and 2. For example:

Boot > boot serialstopbits 2

6

Verify your current changes by entering show at the boot prompt:

Boot > show

Edit buffer contents:

Serial (console) baud : 19200

Serial (console) parity : even

Serial (console) stopbits : 2

Serial (console) wordsize : 7

(additional table output not shown)

7

You can save your changes to the boot.params file by entering commit file at the boot prompt:

Boot > commit file

Note. When the commit file command is used, changes will not be enabled until after the next switch
reboot.

8

You can also save your changes in real time to the switch’s running memory by entering commit

system at the boot prompt:

Boot > commit system

Caution. There are two important things to consider when using the commit system command to save

serial connection changes:

Output to the terminal may become illegible due to incompatible serial connection settings between the
switch and the terminal emulation software.

If you use the commit system command only, changes will not be saved to the switch’s boot.params
file and will be lost if the switch is rebooted. To save changes to the boot.params file, refer to step 7.

9

Return to the CLI prompt by entering exit at the boot prompt.