OmniSwitch 6600 Series Chassis and Hardware Components

Viewing Basic Chassis Information

OmniSwitch 6600 Series Hardware Users Guide

April 2004

page 2-55

Detailed Slot and Component Information

To view more detailed slot and component information, including information on installed uplink and
stacking modules
, use the

show module long

command.

Note. Because OmniSwitch 6600 series switches can also be thought of as Network Interface modules in a
virtual chassis, the

show ni

command displays the same information as the show module long command.

This command displays the following information:

Model name, also referred to as chassis type

Chassis description

Alcatel part number

Hardware revision level

Serial number

Manufacture date(s)

Current power and operational status

Base chassis MAC address (for more information on the base chassis MAC address, see

page 2-59

)

ASIC and firmware information

Detailed information on all installed uplink and stacking modules

Information on all installed MiniGBICs

For example:

-> show module long

CMM in slot 1

Model Name: OS6648 ,

Description: 48PT 10/100 Stack,

Part Number: 902098-10,

Hardware Revision: 210,

Serial Number: 2313283p,

Manufacture Date: FEB 05 2106€,

Firmware Version: N/A,

Admin Status: POWER ON,

Operational Status: UP,

Power Consumption: 40,

Power Control Checksum: 0x0,

MAC Address: 00:d0:95:12:ed:00,

ASIC - Physical: