A slot number is specified, No slot number is specified – Alcatel-Lucent Omni 6624 User Manual

Page 44

Advertising
background image

Back Up Power Supply

OmniSwitch 6600 Series Chassis and Hardware Components

page 2-24

OmniSwitch 6600 Series Hardware Users Guide

April 2004

Viewing Power Supply Status for Stacked Configurations

When entering the show power command on the primary switch in a stacked configuration, you can either
enter only the show power syntax or you can specify a specific slot number. For more information, refer
to the examples below:

A Slot Number is Specified

If you specify a slot number after the command syntax, power supply information for only the correspond-
ing switch displays. For example:

-> show power 2

Power Supplies in chassis 2

PS Operational Status

-----+-------------------

PS-1 UP

PS-2 NOT PRESENT

In the example above, power supply status for the switch operating in slot 2 displays. No back up power
supply is installed in the slot 2 chassis (or the back up power supply is powered off).

No Slot Number is Specified

If you do not enter a slot number, power supply information for all switches in the stack displays. For
example:

-> show power

Power Supplies in chassis 1

PS Operational Status

-----+-------------------

PS-1 UP

PS-2 UP

Power Supplies in chassis 2

PS Operational Status

-----+-------------------

PS-1 UP

PS-2 NOT PRESENT

The example above shows the power supply status for a stack consisting of two switches. A back up power
supply is present and running in the switch operating in slot 1; no back up power supply is installed in the
switch operating in slot 2 (or the unit is powered off).

More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600
series switches, refer to

Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

Advertising
This manual is related to the following products: