BEVEL ARROW ADJUSTMENT

1. Make certain that the blade is at 90-degrees to the

table surface with a combination square.

Fig. 39

2. Check that the bevel arrow is pointing to the zero

degree mark on the bevel scale located on the front
of the cabinet.

3. To adjust arrow, loosen the Philips head screw (A),

and reposition the bevel arrow and tighten screw.

SEE FIG 39.

17

1. To align the blade parallel to the miter slot, first

loosen two hex soc head screws (A) under the front

side of the table saw. This is the same side as the

raise/lower handwheel (B). SEE FIG. 37

Fig.37

A

B

2. Remove the End cap on the rear side of the table

saw, Loosen two hex soc head screws (C). SEE FIG.38

Fig.38

C

3. The saw table is now loose and can be repositioned

until the blade is parallel to the miter slot. Repeat

steps in

4. When blade is parallel to miter slot, tighten all four

hex soc head screws.

5. Recheck blade alignment.

6. Tilt the blade to 45 degrees, and rotate the saw

blade by hand. Make sure the blade does not

contact the table insert.

"CHECKING BLADE ALIGNMENT."