RIKON Power Tools 10-201 User Manual

Page 18

Advertising
background image

TABLE INSERT ADJUSTMENT

Fig. 40

1. The table insert (A) must always be level with the saw

table (B).

2. Place a straight edge across the front and rear of the

table insert. Check that the insert is perfectly level with
the saw table.

3. To level the table insert, turn the one or more adjusting

set screws (C) as needed and recheck.

5. The table insert is equipped with a finger hole (D) for

easy removal. SEE FIG. 40

1. The miter gauge has adjustable positive stops at 0-

degree and 45-degrees or it can be manually set at
any angle between 60-degrees.

2. To rotate miter gauge body (A), loosen knob (B) and

pull out plunger (C) and rotate miter gauge body to
desired angle and tighten knob.

3. To rotate to the next positive stop, pull plunger (C) out,

rotate miter gauge body then push plunger back in and
continue rotating miter gauge body until it stops
Against next positive stop.

SEE FIG. 41

A

B

C

D

C

MITER GAUGE ADJUSTMENT

ADJUSTING POSITIVE STOPS

Fig. 42

E

D

1. To adjust 0-degree positive stops, loosen knob (B), pull

out on plunger (C) and turn miter gauge over.

2. Loosen the lock nut (D) 3 or 4 turns.

3. Place a square against the guide bar and front of the

miter gauge body. Square the miter gauge body to the
guide bar and tighten knob.

4. Push in plunger and make adjustments to stop screw

(E) so that it touches the plunger and tighten lock nut.

5. Recheck the positive stop angle to the saw blade.

insert the guide bar into the miter slot and slide the
miter gauge up to the saw blade.

6. To check, place a square against the saw blade and

miter gauge body. If any more adjustments are needed
repeat steps above.

7. To set both 45-degree positive stops, repeat steps 1

Thru 6 above at the 45-degree settings.

SEE FIG 42.

18

Fig. 41

A

B

C