PROGRAMMING THE EMO-1005


To enter the programming mode press the following key sequence:


CHA

->

DP

->

ENT

->

KFA


Now the display will show:

LINE 1

PROGRAMMING

LINE 2

0 = NO 1 = YES


If this screen did not come up then try the key sequence once more (press
slowly and firmly on the keys). If you would like to program press the 1 key;
if not, press the 0 key. Pressing the 0 key returns the unit to the normal
operating mode. If a 1 was pushed the following screen will appear:

LINE 1

ENTER CHANNEL

LINE 2

NUMBER=??


Enter the channel number that should be programmed and press the ENT key.
NOTE: Channel 1 = 01, 2 = 02 ....


Any mistakes made during programming in the next steps must be edited while at that screen. After
leaving any display you must toggle through the remaining displays to return to the operating screen
display. Then enter the programming mode again and toggle through until you get to the screen where
you want to edit the entered value.








Before entering any new data in any of the programmable parameters, zero out the old data first.
Then start to enter the new number. The numbers will be shifted to left as they are entered.